![]() |
探针法实时荧光试剂盒(带ROX2)
- 品牌:EZBioscience
- 产地:美国
- 货号:EZB-RTProbe-R2-S
- cas:详询
- 发布日期: 2022-09-22
- 更新日期: 2024-08-12
产品详请
产地 | 美国 |
保存条件 | 2-8℃保存 |
品牌 | EZBioscience |
货号 | EZB-RTProbe-R2-S |
用途 | 详询 |
检测方法 | 详询 |
CAS编号 | 详询 |
保质期 | 一年 |
适应物种 | 详询 |
检测限 | 详询 |
数量 | 大量 |
包装规格 | 100 Rxns |
标记物 | 详询 |
纯度 | 详询% |
样本 | 详询 |
应用 | 详询 |
是否进口 | 是 |
20× EZProbe One Step Enzyme Mix contains M-MLV (RNase H-) reverse transcriptase, RNase Inhibitor and Hot Start DNA Polymerase; 2× EZProbe One Step Buffer contains dNTPs, Oligo dT18, Random Hexamer, optimized buffer and ROX2.
The M-MLV Reverse Transcriptase, which is an RNA-dependent DNA polymerase with a significantly attenuated RNase H activity, can synthesize cDNA at a temperature range of 42°C to 60°C and is inactivated during the activation step of the Hot Start DNA Polymerase.
RNase inhibitor can protect RNA templates from degradation.
This buffer has been optimized to allow both reverse transcription and PCR amplification to occur in the same reaction across a wide range of templates.
Hot Start DNA Polymerase requires an activation step at 95°C for 5 minutes, which prevents non-specific amplification during cDNA synthesis.
Appropriate real-time PCR instruments for this kit are as follows:
Bio-Rad CFX96™, CFX384™, iCycler iQ™, iQ™5, MyiQ™, MiniOpticon™, Opticon®, Opticon 2, Chromo4™; Roche LightCycler™ 96, Roche LightCycler™ 480; Eppendorf Mastercycler® ep realplex, realplex 2s; Illumina Eco qPCR; Qiagen/Corbett Rotor-Gene® Q, Rotor-Gene® 3000, Rotor-Gene® 6000; Thermo Scientific PikoReal Cycler; Analytikjena qTOWER 3G; Cepheid SmartCycler®.
ABI 7500, 7500 Fast, Quant-Studio 3, 5, 6, 7, 12K Flex, Dx, ViiA™7; Stratagene MX3000P™, MX3005P™, MX4000™.
The M-MLV Reverse Transcriptase, which is an RNA-dependent DNA polymerase with a significantly attenuated RNase H activity, can synthesize cDNA at a temperature range of 42°C to 60°C and is inactivated during the activation step of the Hot Start DNA Polymerase.
RNase inhibitor can protect RNA templates from degradation.
This buffer has been optimized to allow both reverse transcription and PCR amplification to occur in the same reaction across a wide range of templates.
Hot Start DNA Polymerase requires an activation step at 95°C for 5 minutes, which prevents non-specific amplification during cDNA synthesis.
Appropriate real-time PCR instruments for this kit are as follows:
Bio-Rad CFX96™, CFX384™, iCycler iQ™, iQ™5, MyiQ™, MiniOpticon™, Opticon®, Opticon 2, Chromo4™; Roche LightCycler™ 96, Roche LightCycler™ 480; Eppendorf Mastercycler® ep realplex, realplex 2s; Illumina Eco qPCR; Qiagen/Corbett Rotor-Gene® Q, Rotor-Gene® 3000, Rotor-Gene® 6000; Thermo Scientific PikoReal Cycler; Analytikjena qTOWER 3G; Cepheid SmartCycler®.
ABI 7500, 7500 Fast, Quant-Studio 3, 5, 6, 7, 12K Flex, Dx, ViiA™7; Stratagene MX3000P™, MX3005P™, MX4000™.